Capacity x resolution
EDjr–2.5K 2500 lbf x 2 1000 kgf x 1 10000 N x 10
EDjr–5K 5000 lbf x 5 2000 kgf x 2 20000 N x 20
EDjr–10K 10000 lbf x 10 5000 kgf x 5 50000 N x 50
EDjr–25K 25000 lbf x 20 10000 kgf x 10 100000 N x 100
7:1 Safety factor.
Body Construction is Aircraft quality 2024 Aluminum

Enclosure:

Designed to NEMA4X/IP55. Suitable for continuous outdoor use.

Accuracy:

0.2% of capacity.

Repeatability:

0.2% of capacity.

Display:

128 x 64 dot-graphic LCD display shows all digits 1.0” (26 mm) high plus annunciators and softkeys.

Display update rate:

2 times per second.

Peak hold sampling rate:

2 times per second typical.

RS-232 communication:

Not available. See Dillon EDxtreme.

Calibration:

Traceable to the National Institute of Standards and Technology. Calibration card included.

Battery life:

200 hours typical use with two C-cell alkaline batteries.

Operating temperature:

-4° F to 140° F (-20° to 60° C)

Included with instrument:

Batteries, manual and calibration card.

Optional accessories:

Carry case.